Search results

Jump to navigation Jump to search
  • {{mhttpdpages1|[[Message System]]}} ...sages generated by applications connected to the experiment. See [[Message System]] for details.
    1 KB (187 words) - 16:12, 27 July 2015
  • # Log experimental data to storage device'''[[Event_Filtering|(s)]]''' # Handles the overall Midas '''[[Message_System|System messages]]''' logging
    1 KB (204 words) - 17:49, 14 July 2015
  • <div id="midas.log"></div> == MIDAS Log file ==
    5 KB (797 words) - 16:03, 4 August 2015
  • ; [[Message System #MIDAS Log file |log file]] ;[[Message System]]
    5 KB (661 words) - 16:00, 23 June 2015
  • * '''[[Alarm System]]''' &rarr; ''User and system Alarm'' * '''[[History System]]''' &rarr; ''Chart history of any of the acquisiti
    2 KB (245 words) - 18:09, 11 December 2019
  • By default, {{Utility|name=msysmon}} will log the CPU data etc to the main SYSTEM buffer every 10s. In most experimental setups, this means that the data wil ...monitor and log GPU usage, and temperatures as well as CPU, memory etc. A system only needs to run msysmon or msysmon-nvidia.
    2 KB (280 words) - 09:44, 21 October 2019
  • Log directory is [[Keys in the ODB /Logger tree #/Logger/Data dir | <def Data directory is same as Log unless specified in channels/
    5 KB (761 words) - 17:47, 14 July 2015
  • ...so the path of the midas message log file [[Message System#midas.log|midas.log]] and paths of the MIDAS stylesheet and Javascript library that are useful
    1 KB (163 words) - 16:05, 27 July 2015
  • Message file midas.log Log messages 0
    3 KB (364 words) - 14:43, 7 July 2015
  • * [[Alarm System]] ...s tree contains user and system information related to alarms (see [[Alarm System]]). The information from this tree is displayed in the [[Alarms Page]].
    16 KB (1,933 words) - 15:57, 6 August 2015
  • * the message log file (unless overruled by [[#/Logger/Message File | Message File]]), ** [[History System|MIDAS history files]] (unless overruled by [[#/Logger/History dir | History
    14 KB (2,191 words) - 05:48, 11 November 2022
  • The following information has been incorporated in [[Alarm System]] = Notes on the implementation of the MIDAS alarm system. =
    3 KB (472 words) - 17:42, 12 November 2015
  • Three Run States define the states of the MIDAS DAQ system: ...tion for a run transition. This notification is done by registering to the system for a given transition ( [[cm_register_transition()]] ) by specifying the t
    5 KB (814 words) - 04:58, 26 January 2016
  • * [[History System]] The ODB /History tree contains information related to the [[History System]].
    18 KB (2,099 words) - 11:36, 24 June 2020
  • The ODB /Equipment tree contains user and system information related to a frontend. Buffer STRING 1 32 9h 0 RWD SYSTEM
    24 KB (2,713 words) - 02:08, 2 May 2024
  • ...hat Page]]). The chat messages are not saved in the [[Message System#MIDAS Log file|MIDAS logfile]].
    2 KB (246 words) - 20:18, 3 February 2016
  • ...or each transaction to a log file {{Filepath|path=/tmp/mserver.log}}. The log entry contains the time stamp and RPC call request. ...py of <span style="color:darkcyan;">''mserver''</span> can be started on a system, provided they use different tcp ports. This is useful if, for example, [[e
    5 KB (692 words) - 17:15, 12 November 2015
  • === <span style="color: purple;">''Log messages''</span> === ...y in the [[#Settings subtree|Settings subtree]] is a bit-field for logging system messages as message events along with the event data from the experiment.
    23 KB (3,373 words) - 16:09, 22 May 2019
  • * [[History System]] It is possible to use the midas history system to periodically record images from a network-connected webcam, for later pl
    3 KB (550 words) - 10:55, 25 June 2020
  • "SYSTEM", // event buffer 0, // log history
    19 KB (2,562 words) - 08:19, 5 January 2024
  • | data-x-log || scatter, histogram || Use logarithmic X-axis if "true" | data-y-log || scatter, histogram || Use logarithmic Y-axis if "true"
    8 KB (1,162 words) - 05:37, 1 May 2024
  • ...e data. There are also keys to customize the [[Message System |Messaging]] system. relevent to storing the [[History System | History]] and [[Elog]] data files.
    7 KB (668 words) - 04:20, 17 November 2022
  • ...]], and as a message on any windows running [[odbedit]] clients. The alarm system is flexible and can be extensively customized for each experiment ...p and activation is done through the '''[[/Alarms ODB tree]]'''. The alarm system includes several other features such as sequencing and control of the exper
    16 KB (2,531 words) - 07:32, 5 May 2023
  • ...age. While there are many ways to do this independently of the acquisition system, the lazylogger provides a simple way to manage this task. Lazylogger featu ...tory, and contain the operational parameters of the channel(s). Two hidden log files for each channel are created and updated ans resides in the main expe
    15 KB (1,896 words) - 11:23, 1 December 2020
  • ...idas system diagram]] to see how these elements interact to form the MIDAS system. *Message System - ''Dedicated buffer system to handle Midas internal messages'' -
    18 KB (2,954 words) - 18:11, 4 January 2016
  • ...Structure|the ODB Structure]] and a list of all the ODB trees used by the system can be found in [[Online Database]]. The ODB is hierarchically structured, similar to a file system, with directories and sub-directories (or trees and subtrees). The data are
    22 KB (3,531 words) - 14:21, 20 June 2023
  • = MIDAS Slow Control System= ...the ODB. If several types of hardware are to be included in a Slow Control System, they may be assigned to a separate Slow Control Equipments. Each Slow Cont
    11 KB (1,360 words) - 04:44, 1 May 2024
  • The history system is an add-on capability built into the MIDAS data logger [[mlogger]] to rec Since June 2020, it is possible to also use the midas history system to record images (png/jpeg etc) periodically, for example to later produce
    31 KB (4,681 words) - 09:56, 30 July 2020
  • ...l bomb and there will be a message in the [[Message System#midas.log|Midas log file]] rejecting the connection from unallowed host 'ladd21.triumf.ca'. ...ts</span>, you should see messages in the [[Message System#midas.log|Midas log file]] about reloading the access control list
    12 KB (1,929 words) - 14:12, 19 June 2023
  • "SYSTEM", // event buffer 0, // don't log history
    6 KB (753 words) - 14:59, 14 July 2015
  • Midas uses a Remote Procedure Call (RPC) system to allow different midas clients to talk to each other directly. One client Internally, midas uses the RPC system to handle run transitions, ODB hotlinks and more.
    10 KB (1,542 words) - 16:58, 26 April 2023
  • -E only display ELog system ...the [[Message Page]], which shows messages generated by the MIDAS [Message System]] as well as the user using cm_msg() functions.
    13 KB (2,014 words) - 09:01, 25 October 2021
  • ...re are several ways of doing this. The ASCII string may be supplied to the system as the [[Equipment List Parameters#Bank Definition/Init String|init string] 0, /* log history */
    13 KB (2,022 words) - 12:12, 4 May 2022
  • Attributes = Run number, Author, Type, System, Subject Options System = General, DAQ, Detector, Electronics, Target, Beamline
    8 KB (1,206 words) - 18:24, 12 January 2024
  • * Destination buffer name (SYSTEM if destination event goes to logger). Log history INT 1 4 18h 0 RWD 0
    7 KB (873 words) - 15:15, 10 August 2015
  • * [[Slow Control System]] ...h frontend. We will first document every feature supported by the frontend system, then explain a slightly more user-friendly wrapper (mfed.cxx) that helps r
    41 KB (5,523 words) - 15:45, 8 January 2024
  • ...in midas banks that can eventually get logged to file or the midas history system. If you don't need to produce data, you can write midas clients without usi ...TMFE::Msg()</code> (a wrapper around <code>cm_msg()</code>) if you want to log an error.
    28 KB (4,108 words) - 16:08, 26 April 2023
  • by the system. * A message event (ID 0x8002) is created if Log messages is enabled in the logger channel setting. The message is contained
    7 KB (1,117 words) - 17:51, 29 October 2013
  • The message log (see [[Message System]]) can be accessed from a custom page using a call to the JavaScript librar = Generate a message log entry =
    39 KB (6,044 words) - 16:25, 28 May 2019
  • | [[File:Capture_sgas.png|thumb|left|Figure 1: MEG Gas System]] || '''Example 1''' This page (Figure 1) from the MEG experiment at PSI shows a complex gas system. This shows the use of "fills" and "labels". Open valves are represented as
    39 KB (5,727 words) - 18:22, 25 March 2024
  • Log on to the ''[[#Introduction|Experiment Host]]'' and decide on a name for th ...ath=$HOME/online}} will contain the MIDAS messages file ({{File|name=midas.log}}) and
    38 KB (5,821 words) - 03:18, 3 January 2024